{"id":4398,"date":"2022-01-30T12:47:22","date_gmt":"2022-01-30T12:47:22","guid":{"rendered":"https:\/\/mira-lab.com\/?post_type=product&#038;p=4398"},"modified":"2022-01-31T12:29:27","modified_gmt":"2022-01-31T12:29:27","slug":"protein-c","status":"publish","type":"product","link":"https:\/\/mira-lab.com\/new\/product\/protein-c\/","title":{"rendered":"PROTEIN C"},"content":{"rendered":"<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-4399 alignleft\" src=\"https:\/\/mira-lab.com\/wp-content\/uploads\/2022\/01\/Untitled-14.jpg\" alt=\"\" width=\"426\" height=\"370\" srcset=\"https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-14.jpg 1170w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-14-270x235.jpg 270w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-14-570x495.jpg 570w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-14-320x278.jpg 320w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-14-768x668.jpg 768w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-14-540x469.jpg 540w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-14-600x522.jpg 600w\" sizes=\"auto, (max-width: 426px) 100vw, 426px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>The kit is intended for the detection of protein C activity in human blood plasma to diagnose innate and acquired deficit of this anticoagulant.<br \/>\nPrinciple. Method of detection of protein C activity in blood plasma is based on the ability of activated protein C to hydrolyze peptide chromogen<br \/>\nsubstrate. Quantity of released dye pNA is in direct proportion to activity of protein C in plasma sample. Protein C of plasma is activated by<br \/>\nadding of purified extract of Agkistrodon contortrix contortrix toxin. Process has following scheme:<br \/>\nProtein C + activator (surplus) ==&gt; Activated protein C<br \/>\nActivated protein C + peptide \u2013 pNA ==&gt; peptide + pNA<\/p>\n<p><strong>REACHROM PROTEIN C \u2013 TEST<\/strong><br \/>\n<strong>The kit of reagents for the determination protein C activity by<\/strong><br \/>\n<strong>photometric method<\/strong><br \/>\nCat. # PFA-5 for 20-100 assays.<br \/>\nReagents:<br \/>\n&#8211; concentrated buffer (2 mL) \u2013 1 vial;<br \/>\n&#8211; protein C activator (5 mL), lyophilized \u2013 2 vials;<br \/>\n&#8211; standard plasma (1 mL), lyophilized \u2013 1 vial;<br \/>\n&#8211; chromogenic substrate (2 mL), lyophilized \u2013 2 vials<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>PROREIN C Screening Test<\/strong><br \/>\n<strong>The kit of reagents for the<\/strong><br \/>\n<strong>determination of total activity of<\/strong><br \/>\n<strong>protein C system.<\/strong><br \/>\nCat. # PFA-3-for 40-80 assays.<br \/>\nThe kit is intended for the detection of innate or acquired deficiency of<br \/>\nprotein C system and for the detection mutant factor V (Leiden), resistant to<br \/>\nprotein C, by clotting method.<img decoding=\"async\" loading=\"lazy\" class=\"wp-image-4466 alignright\" src=\"https:\/\/mira-lab.com\/wp-content\/uploads\/2022\/01\/Untitled-15.png\" alt=\"\" width=\"411\" height=\"261\" srcset=\"https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15.png 694w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-270x171.png 270w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-570x361.png 570w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-320x203.png 320w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-540x342.png 540w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-600x380.png 600w\" sizes=\"auto, (max-width: 411px) 100vw, 411px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>ReaPrC\/FV Test<\/strong><br \/>\n<strong>The kit of reagents for the determination<\/strong><br \/>\n<strong>of total activity of protein C system.<\/strong><br \/>\nCat. # PFA-4-for 10-20 assays.<br \/>\nNew form of hereditary thrombophilia is characterized. In the base of this form factor V Leiden presents among patients.<br \/>\nMain of this form is that factor V Leiden<br \/>\n(mutant factor V of coagulation system) has resistance to the action of activated<br \/>\nprotein C, that leads to increase of internal and external coagulation ways and raises frequency of thrombosis: thrombosis of<br \/>\nperipheral veins, myocardial infarction, thromboembolism of pulmonary artery,<br \/>\nthrombosis of retina veins and others.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-4466 alignright\" src=\"https:\/\/mira-lab.com\/wp-content\/uploads\/2022\/01\/Untitled-15.png\" alt=\"\" width=\"417\" height=\"265\" srcset=\"https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15.png 694w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-270x171.png 270w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-570x361.png 570w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-320x203.png 320w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-540x342.png 540w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-15-600x380.png 600w\" sizes=\"auto, (max-width: 417px) 100vw, 417px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>CONTROL PLASMA with normal and<\/strong><br \/>\n<strong>abnormal level of anticoagulation<\/strong><br \/>\n<strong>system of protein C<\/strong><br \/>\nThe kit of reagents for the determination of total activity of protein C system.<br \/>\nCat. # PFA-6\/7: normal level (1ml)-3 vials, abnormal level (1ml)-3 vials.<br \/>\nControl plasma with normal level of anticoagulation system of protein C is used for control the detection of total<br \/>\nactivity of protein C system and for<br \/>\nthe detection of resistance of activated FVa to the action of activated protein<br \/>\nC. It is used with the kits \u201cProtein C<br \/>\ntest\u201d and \u201cReaPrC\/FV test\u201d.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-4467 alignright\" src=\"https:\/\/mira-lab.com\/wp-content\/uploads\/2022\/01\/Untitled-17.png\" alt=\"\" width=\"433\" height=\"281\" srcset=\"https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-17.png 663w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-17-270x175.png 270w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-17-570x369.png 570w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-17-320x207.png 320w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-17-540x349.png 540w, https:\/\/mira-lab.com\/new\/wp-content\/uploads\/2022\/01\/Untitled-17-600x388.png 600w\" sizes=\"auto, (max-width: 433px) 100vw, 433px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The kit is intended for the detection of protein C activity in human blood plasma to diagnose innate and acquired deficit of this anticoagulant. Principle. Method of detection of protein C activity in blood plasma is based on the ability of activated protein C to hydrolyze peptide chromogen substrate. Quantity of released dye pNA is in direct proportion to activity of protein C in plasma sample. Protein C of plasma is activated by adding of purified extract of Agkistrodon contortrix contortrix toxin. Process has following scheme: Protein C + activator (surplus) ==&gt; Activated protein C Activated protein C + peptide \u2013 pNA ==&gt; peptide + pNA REACHROM PROTEIN C \u2013 TEST The kit of reagents for the determination protein C activity by photometric method Cat. # PFA-5 for 20-100 assays. Reagents: &#8211; concentrated buffer (2 mL) \u2013 1 vial; &#8211; protein C activator (5 mL), lyophilized \u2013 2 vials; &#8211; standard plasma (1 mL), lyophilized \u2013 1 vial; &#8211; chromogenic substrate (2 mL), lyophilized \u2013 2 vials &nbsp; &nbsp; &nbsp; PROREIN C Screening Test The kit of reagents for the determination of total activity of protein C system. Cat. # PFA-3-for 40-80 assays. The kit is intended for the detection of innate or acquired deficiency of protein C system and for the detection mutant factor V (Leiden), resistant to protein C, by clotting method. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; ReaPrC\/FV Test The kit of reagents for the determination of total activity of protein C system. Cat. # PFA-4-for 10-20 assays. New form of hereditary thrombophilia is characterized. In the base of this form factor V Leiden presents among patients. Main of this form is that factor V Leiden (mutant factor V of coagulation system) has resistance to the action of activated protein C, that leads to increase of internal and external coagulation ways and raises frequency of thrombosis: thrombosis of peripheral veins, myocardial infarction, thromboembolism of pulmonary artery, thrombosis of retina veins and others. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; CONTROL PLASMA with normal and abnormal level of anticoagulation system of protein C The kit of reagents for the determination of total activity of protein C system. Cat. # PFA-6\/7: normal level (1ml)-3 vials, abnormal level (1ml)-3 vials. Control plasma with normal level of anticoagulation system of protein C is used for control the detection of total activity of protein C system and for the detection of resistance of activated FVa to the action of activated protein C. It is used with the kits \u201cProtein C test\u201d and \u201cReaPrC\/FV test\u201d. &nbsp; &nbsp; &nbsp; &nbsp;<\/p>\n","protected":false},"featured_media":4399,"template":"","meta":{"nf_dc_page":""},"product_brand":[],"product_cat":[206],"product_tag":[],"class_list":["post-4398","product","type-product","status-publish","has-post-thumbnail","product_cat-renam","cms-has-post-thumbnail","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/mira-lab.com\/new\/wp-json\/wp\/v2\/product\/4398","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mira-lab.com\/new\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/mira-lab.com\/new\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mira-lab.com\/new\/wp-json\/wp\/v2\/media\/4399"}],"wp:attachment":[{"href":"https:\/\/mira-lab.com\/new\/wp-json\/wp\/v2\/media?parent=4398"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/mira-lab.com\/new\/wp-json\/wp\/v2\/product_brand?post=4398"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/mira-lab.com\/new\/wp-json\/wp\/v2\/product_cat?post=4398"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/mira-lab.com\/new\/wp-json\/wp\/v2\/product_tag?post=4398"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}