Cryometrix T-160 Ultra Low Temp Freezer
The Cryometrix T-160 Ultra-Low Temperature Freezer is a powerful cryogenic freezer, capable of reaching temperatures as low as -160°C. Using a contained liquid nitrogen system, the T-160 doesn’t expose user or product to liquid nitrogen. By removing the need for a mechanical compressor, the T-160 requires little electricity and practically no maintenance.
Reaching -160°C traditionally required large vat freezers that immerse the product in liquid nitrogen. The T-160 replaces this expensive and dangerous practice with one as simple as a household refrigerator.
Cryometrix Liquid Nitrogen Technology is patented and patent pending.
Physical Property | Metric | Imperial |
---|---|---|
Dimensions (Depth x Width x Height) | 1062 mm x 1224 mm x 2126 mm | 41.8″ x 48.2″ x 83.7″ |
Weight | 624 kg | 1372 lbs. |
Payload Capacity | 900 L | 31.7 ft3 |
2mL Vial Capacity | 57,600 | 57,600 |
Payload Dimensions (Depth x Width x Height) | 673 mm x 876 mm x 1524 mm | 26.5″ x 34.5″ x 60″ |
Electrical | 208 – 240 VAC | 120 VAC, 60 Hz |
LN2 Inlet Pressure | 207 – 414 kPa | 30 – 60 PSI |
Adjustable Set Point | 40°C to -160°C | 104°F to -256°F |
Temperature Uniformity | 7°C ± at -160°C 3°C ± at -80°C |
7°F ± at -256°F 5°F ± at -130°F |
Cool Down Time 20°C to -80°C | 45 min | 45 min |
Cool Down Time 20°C to -160°C | 150 min | 150 min |
Powerful Innovation
- Next-Gen Liquid Nitrogen Tech
- Cryometrix freezers don’t use traditional mechanical compressors. Mechanical compressors utilize refrigerants, an example being freon, to produce cold temperatures. These are noisy and use large amounts of electricity.
- LN2 has a boiling point of -196°C, enabling freezers who use it to go to temperatures as low as -196°C. Most refrigerants have boiling points greater than -100°C, making it difficult for freezers using them to operate at temperatures below that.
- Low Energy Usage
- Cryometrix freezers use 7x less electricity than comparable lab freezers.
- LN2 operates on pressure and requires no electricity to function, enabling it to function without power in an emergency situation.
- Extreme Reliability
- Cryometrix freezers don’t require HVAC systems to cool the ambient temperature in order to operate. They can operate in any ambiance, and actually cool the environment around it.
- There are practically no moving parts on Cryometrix freezers, making them last up to 4 times as long as comparable lab freezers with hardly any maintenance.
- Are practically silent when in operation.
- Easily Expandable
- Cryometrix freezers consume little electricity, enabling the customer to add units to their facility with zero electrical complications.
- The effective footprint is below 8 square feet and little to no space is needed on the sides, easily fitting into any facility.
- Extreme Versatility
- Many liquid nitrogen freezers directly expose the product to the nitrogen, limiting its usage. The T-160 Storage Freezer uses a contained liquid nitrogen system, enabling the low temperature of liquid nitrogen technology with the flexibility of traditional compressor-based systems.
- 20 Year Warranty
- Cryometrix freezers automatically come with a 20-year warranty on their cooling systems.
Environment Friendly
- Clean Emissions
- Cryometrix freezers only emit nitrogen outside your building, which already makes up over 75% of the Earth’s atmosphere.
- Long-Lasting
- The cooling system of Cryometrix freezers are built to last 20 years, with a warranty to cover it.
Cost Efficient
- Space Efficient
- Cryometrix freezers have the smallest footprint for its volume, costing less in floor space and allowing you to fit more units in your current space.
- Simple Design
- The upright design allows for quick and convenient access, reducing labor costs and risks.
- Low Energy Costs
- LN2 technology uses much less electricity than traditional compressor-based technologies.
- Cryometrix freezers don’t need energy intensive HVAC systems to operate efficiently.
- Efficient LN2 Usage
- The T-160 doesn’t waste the nitrogen it uses, maximizing capability.
Complete Safety
- Closed Nitrogen System
- There is zero contact between LN2 and the operator or product.
- LN2 storage is simple and completely autonomous.
- Unreactive
- Nitrogen isn’t flammable or explosive like many refrigerants used in compressor-based technologies.
- Easy Cleaning
- The 100% stainless steel interior/exterior of the freezer is easy to clean without harsh industrial chemicals.
Sample Integrity
- Closed System
- No LN2 is exposed to the sample, maintaining the samples integrity.
- Data-Logging
- Cryometrix freezers automatically track temperature and other useful data.
- Emergency Valve
- Cryometrix freezers have redundant manual valves that can be used during a power outage to maintain the temperature in the payload bay.
- Temperature Uniformity
- Multiple fans create a high flux of airflow to maintain uniform temperature within the payload bay.