Cryometrix T-160 Ultra Low Temp Freezer

Category:

Cryometrix T-160 Liquid Nitrogen ULT Freezer right side.

The Cryometrix T-160 Ultra-Low Temperature Freezer is a powerful cryogenic freezer, capable of reaching temperatures as low as -160°C. Using a contained liquid nitrogen system, the T-160 doesn’t expose user or product to liquid nitrogen. By removing the need for a mechanical compressor, the T-160 requires little electricity and practically no maintenance.

Reaching -160°C traditionally required large vat freezers that immerse the product in liquid nitrogen. The T-160 replaces this expensive and dangerous practice with one as simple as a household refrigerator.

Cryometrix Liquid Nitrogen Technology is patented and patent pending.

Physical Property Metric Imperial
Dimensions (Depth x Width x Height) 1062 mm x 1224 mm x 2126 mm 41.8″ x 48.2″ x 83.7″
Weight 624 kg 1372 lbs.
Payload Capacity 900 L 31.7 ft3
2mL Vial Capacity 57,600 57,600
Payload Dimensions (Depth x Width x Height) 673 mm x 876 mm x 1524 mm 26.5″ x 34.5″ x 60″
Electrical 208 – 240 VAC 120 VAC, 60 Hz
LN2 Inlet Pressure 207 – 414 kPa 30 – 60 PSI
Adjustable Set Point 40°C to -160°C 104°F to -256°F
Temperature Uniformity 7°C ± at -160°C
3°C ± at -80°C
7°F ± at -256°F
5°F ± at -130°F
Cool Down Time 20°C to -80°C 45 min 45 min
Cool Down Time 20°C to -160°C 150 min 150 min

Powerful Innovation

  • Next-Gen Liquid Nitrogen Tech
    • Cryometrix freezers don’t use traditional mechanical compressors. Mechanical compressors utilize refrigerants, an example being freon, to produce cold temperatures. These are noisy and use large amounts of electricity.
    • LN2 has a boiling point of -196°C, enabling freezers who use it to go to temperatures as low as -196°C. Most refrigerants have boiling points greater than -100°C, making it difficult for freezers using them to operate at temperatures below that.
  • Low Energy Usage
    • Cryometrix freezers use 7x less electricity than comparable lab freezers.
    • LN2 operates on pressure and requires no electricity to function, enabling it to function without power in an emergency situation.
  • Extreme Reliability
    • Cryometrix freezers don’t require HVAC systems to cool the ambient temperature in order to operate. They can operate in any ambiance, and actually cool the environment around it.
    • There are practically no moving parts on Cryometrix freezers, making them last up to 4 times as long as comparable lab freezers with hardly any maintenance.
    • Are practically silent when in operation.
  • Easily Expandable
    • Cryometrix freezers consume little electricity, enabling the customer to add units to their facility with zero electrical complications.
    • The effective footprint is below 8 square feet and little to no space is needed on the sides, easily fitting into any facility.
  • Extreme Versatility
    • Many liquid nitrogen freezers directly expose the product to the nitrogen, limiting its usage. The T-160 Storage Freezer uses a contained liquid nitrogen system, enabling the low temperature of liquid nitrogen technology with the flexibility of traditional compressor-based systems.
  • 20 Year Warranty
    • Cryometrix freezers automatically come with a 20-year warranty on their cooling systems.

Environment Friendly

  • Clean Emissions
    • Cryometrix freezers only emit nitrogen outside your building, which already makes up over 75% of the Earth’s atmosphere.
  • Long-Lasting
    • The cooling system of Cryometrix freezers are built to last 20 years, with a warranty to cover it.

Cost Efficient

  • Space Efficient
    • Cryometrix freezers have the smallest footprint for its volume, costing less in floor space and allowing you to fit more units in your current space.
  • Simple Design
    • The upright design allows for quick and convenient access, reducing labor costs and risks.
  • Low Energy Costs
    • LN2 technology uses much less electricity than traditional compressor-based technologies.
    • Cryometrix freezers don’t need energy intensive HVAC systems to operate efficiently.
  • Efficient LN2 Usage
    • The T-160 doesn’t waste the nitrogen it uses, maximizing capability.

Complete Safety

  • Closed Nitrogen System
    • There is zero contact between LN2 and the operator or product.
    • LN2 storage is simple and completely autonomous.
  • Unreactive
    • Nitrogen isn’t flammable or explosive like many refrigerants used in compressor-based technologies.
  • Easy Cleaning
    • The 100% stainless steel interior/exterior of the freezer is easy to clean without harsh industrial chemicals.

Sample Integrity

  • Closed System
    • No LN2 is exposed to the sample, maintaining the samples integrity.
  • Data-Logging
    • Cryometrix freezers automatically track temperature and other useful data.
  • Emergency Valve
    • Cryometrix freezers have redundant manual valves that can be used during a power outage to maintain the temperature in the payload bay.
  • Temperature Uniformity
    • Multiple fans create a high flux of airflow to maintain uniform temperature within the payload bay.
No products in the cart.